Tigo SF

TIGO SF is an accurate and compact CMM specifically designed for use on the shop floor. With a measurement volume of 500 x 580 x 500 mm (X/Y/Z), it is the ideal measurement solution for a wide range of small and medium size parts from all industrial sectors.

Let’s start project together!

Tell us about your project and we’ll get back to you within 24 hours.

    What is your name?*

    What company do you represent?

    Phone number?*

    A few words about your project*

    Technology Inside

    Scan Pilot

    Guiding the CMM through the unknown
    Scanning of unknown paths can often be challenging and time-consuming. The advanced firmware algorithms of Scan Pilot offer greater motion control capabilities that ensure robust scanning performance.

    Fly2 Mode

    Gliding smoothly through the measurements
    Fly2 Mode further optimises machine motion and minimises idle times so that the machine glides smoothly through its movement trajectories. As a result, program execution times are decreased considerably

    Eco Mode

    Save energy, sustain the environment
    Eco Mode was implemented to reduce the operating cost of CMMs by decreasing energy consumption, and to help protect and sustain the environment. Eco Mode automatically powers down the machine when it stands idle.

    XT 40 °C

    Extended
    temperature

    A network of thermal sensors combined with enhanced structural machine temperature compensation, ensures optimum machine performance in harsh environments even at high temperatures and gradients.

    TIGO SF specifications

    Articulating head with scanning probe HP-S-X1S, Scanning probe heads HP-S- X1C

    Max. Permissible Error MPE (µm) and Max. Permissible Limit
    MPL (µm) according to ISO 10360-2:2009
    Volumetric length measuring error 1)Repeatability range
    MPE(E0/E60)MPL(R0)
    Temperature range T1 (T1: 18 - 22 °C)2.2 + L/3001.6
    Temperature range T2 (T2: 16 - 26 °C)2.5 + L/250
    Temperature range T3 (T3: 15 - 30 °C))2.7 + L/200
    Temperature range T4 - XT option: (T4: 15 - 40 °C)3.7 + L/100
    Temperature range T5 - XT option (T5: 15 - 40 °C)3.7 + L/80
    Max. Permissible Error MPE (µm) according to ISO 10360-5:2010
    Single stylus form errorMPE(PFTU)2.2
    Max. Permissible Error MPE (µm) and Max. Permissible Time MPT (s) according to ISO 10360-4:2000
    Single stylus form error, scanning 2)MPE(THP)/MPT(τ)3.5/50

    Articulating head with HP-THDe trigger probe

    Max. Permissible Error MPE (µm) and Max. Permissible Limit
    MPL (µm) according to ISO 10360-2:2009
    Volumetric length measuring error 1)Repeatability range
    MPE(E0/E60)MPL(R0)
    Temperature range T1 (T1: 18 - 22 °C)2.4 + L/3001.8
    Temperature range T2 (T2: 16 - 26 °C)2.7 + L/250
    Temperature range T3 (T3: 15 - 30 °C))2.9 + L/200
    Temperature range T4 - XT option: (T4: 15 - 40 °C)3.9 + L/100
    Temperature range T5 - XT option (T5: 15 - 40 °C)3.9 + L/80
    Max. Permissible Error MPE (µm)
    according to ISO 10360-5:2010
    Single stylus form errorMPE(PFTU)2.4

    Articulating head with HP-TMe trigger probe

    Max. Permissible Error MPE (µm) and Max. Permissible Limit MPL (µm)
    according to ISO 10360-2:2009
    Volumetric length measuring error 1)Repeatability range
    MPE(E0/E60)MPL(R0)
    Temperature range T1 (T1: 18 - 22 °C) 2.6 + L/3002.0
    Temperature range T2 (T2: 16 - 26 °C)2.9 + L/250
    Temperature range T3 (T3: 15 - 30 °C))3.1 + L/200
    Temperature range T4 - XT option: (T4: 15 - 40 °C)4.1 + L/100
    Temperature range T5 - XT option (T5: 15 - 40 °C)4.1 + L/80
    Max. Permissible Error MPE (µm) according to ISO 10360-5:2010
    Single stylus form errorMPE(PFTU)2.6
    Dynamics
    Max. 3D Speed520 mm/s
    Max. 3D Acceleration1750 mm/s2
    Max. Scanning Speed300 mm/s
    Performance test according to the following specificationAmbient temperatureMax. air temperature varMax. gradient in space
    Temperature range T118 °C - 22 °C1 °C/h - 2 °C/24h1 °C/m
    Temperature range T216 °C - 26 °C1 °C/h - 5 °C/24h
    Temperature range T315 °C - 30 °C2 °C/h - 5 °C/24h
    Temperature range T415 °C - 40 °C2 °C/h - 5 °C/24h
    Temperature range T515 °C - 40 °C2 °C/h - 10 °C/24h

    Probe heads and sensors

    Technical characteristicsHP-S-X1C
    Overtravel range± 2 mm in all axes
    Stylus jointM3
    Max. stylus weight33 g
    Max. stylus lengthVertical: up to 225 mm
    Horizontal: up to 100 mm
    Technical characteristicsHH-A-M5 / HH-A-T5
    Indexable Probe Head
    HH-A-M7.5 / HH-A-T7.5
    Indexable Probe Head
    Angular rotationA axis: +90° / -115°
    B axis: ±180°
    A axis: +105° / 0°
    B axis: ±180°
    Angular rotation step5°7.5°
    Max. applied torque0.6 Nm
    Max. extension length300 mm

    Technical characteristics

    CharacteristicsSpecifications
    Mechanical frameX: T Frame made of welded steel;
    Y carriage: made in steel;
    Z axis: Micromachined steel extrusion
    Surface plateMaterial: Granite
    Flatness: according to DIN 876/III
    Part Locking: threaded inserts M8 x 1.25e
    WeightMax. Part Weight: 150 kg; CMM Weight approx.: 800 kg
    Sliding systemDual lineas guide with recirculating ball bearings on all axes
    Measuring systemMETALLUR® linear scales. System Resolution: 0.039 μm
    Temperature compensationMulti-sensor temperature compensation technology
    Ram counterbalanceSteel spring
    Supply RequirementsPower. 100/120/230/240 V ± 10% - 50/60 Hz - 2.5 KVA (+0.7 KVA - XT option)
    Air. no air required
    ConsumptionPower. 0.4 KVAh (+0.55 KVAh - XT option)
    Operating SpecificationsAmbient temperature: 10 - 40 °C
    Relative humidity: 20% - 90 % non-condensing

    Let’s start project together!

    Please fill out the form to request a quote. We will get back to you within 24 hours of receiving your request. Thank you for your patience

      What is your name?*

      What company do you represent?*

      Phone number?*

      Tell us about your project or application*